Skip to content
Heat pump installation in Hazel Grove: a Stiebel Eltron air source heat pump on a concrete plinth beside a detached house and a striped lawn, its pipework running into the wall and an isolator switch beside it

Heat Pump Installation In Hazel Grove, Planned While Your Gas Boiler Still Works

Get an air source heat pump designed for your Hazel Grove house now, with each room measured and the running cost set against your gas, so you can decide before the old boiler fails.

  • Gas Safe Register mark, First Point gas engineer registration 930763
  • F-Gas Register mark, First Point registration FGAS3028681
  • Heat Geek trained
  • Stiebel Eltron certified installer
  • Which? Trusted Trader
Finance through Ideal4Finance

Spread The Cost Of A Heat Pump

  • APR (fixed) 12.9%
  • Loans from £1 to £30,000
  • Finance over 12 to 120 months
  • Ask for finance with your heat pump quote
  • We agree any deposit with you before you apply

Representative example: £8,000 purchase, £2,000 deposit, £6,000 credit over 48 months at 12.9% APR (fixed). 48 monthly payments of £160.67. Total repayable £7,712.03. Total cost £9,712.03.

First Point Plumbing & Heating is an Introducer Appointed Representative of Ideal Sales Solutions Ltd, t/a Ideal4Finance. Ideal Sales Solutions Ltd is a credit broker and not a lender (FRN 703401). Finance available subject to status. There are risks involved in taking out a loan and you should ensure you can make all payments on time and in full; failure to do so can lead to financial difficulties and have a negative impact on your credit score.

Heat pump installation in Hazel Grove: interior of a semi-detached living room (copy) /: vertical composite of a heat pump on a stone wall plus an install-only gritstone terrace shot (copy)

A Gas Boiler That Breaks Down In January Leaves No Time To Weigh Up A Heat Pump

A heat pump needs a survey and a design first, then a week to a month on site, and a cold house won’t wait that long.

About six in seven Hazel Grove households heat with mains gas alone. Chances are your home has a gas boiler working away today.

Leave the heat pump question until that boiler stops, and you face a cold house and a rushed replacement. The same gas bill then runs for years to come.

Ask while it still runs and you get the survey, the design and the sums against your gas with time to read them.

If one of these is the question you’d want answered first:

  • “I’m scared heat pumps don’t work.”
  • “Can I get the grant?”
  • “Is it too early to ask while my boiler works?”
  • “Am I tied in once the survey’s done?”

The first gets answered by a design for your rooms, worked out from our lead engineer’s own measurements. The second gets a straight answer at the survey: grant claims need MCS certification, and ours is in progress.

You get the figures while the old boiler still works, and the decision stays yours.

Heat Pump Installers Covering Hazel Grove, Along The A6

The same team handles the survey, the install and any return visit.

  • A design aimed at SCOP 3.5 to 4.0 where the house allows it, with the running cost against your gas in the quote

  • Where gas stays cheaper for your house, the turn-down promise has us say so before you spend anything

  • One engineer who measures your rooms, draws the design and leads the fit, with no selling on the survey

  • A 2-year guarantee on our workmanship, alongside the manufacturer’s warranty

Heat pump installation in Hazel Grove: engineer with homeowner, faces shown (copy) /: crew at the liveried van plus a heat loss survey frame (copy, thermal max 2)

A Hazel Grove Heat Pump, Sized Before A Single Part Is Ordered

Scroll and the outdoor unit builds up in design order: your rooms’ heat loss sets the size, and the parts follow it.

  1. Your House Sets The Size

    Room-by-room heat loss calculation first, on our own measurements.

    • Stone Wall
    • Wall Bracket
    • Base Tray
    • Coil
    • Fan Motor
    • Fan
  2. Then The Unit Is Chosen

    The outdoor unit is picked to match the figure your house produced rather than a standard size.

    • Compressor
    • Front Panel
    • Fan Guard
    • Top Panel
  3. Emitters And Pipework Sized With It

    Underfloor loops only where the number calls for them, and the design names which radiators grow.

    • Refrigerant Lines
    • Flow Pipe
    • Return Pipe
  4. Commissioned To The Numbers

    Proved on site against the same design figures, with the warranty registered in your name.

    • Service Panel
    • Controls
    • Cable

Six Stages In Your Hazel Grove Heat Pump Installation Quote

Each stage below sits in one fixed price, so you can compare it line by line with any other quote you hold.

  1. 1. Free Design Survey

    Our lead engineer measures each room and walks the outside of the house for the unit’s spot, and the survey stays a measuring visit.

    Heat pump installation in Hazel Grove: step 4, balanced radiators
  2. 2. A Design You Can Check

    Room-by-room heat loss, the unit and radiators sized to it, the pipe runs, and the running-cost sums against your gas boiler.

    Heat pump installation in Hazel Grove: step 3, radiators balanced
  3. 3. A Fixed Price

    The price in writing is the price you pay.

    Heat pump installation in Hazel Grove: step 3, a fixed quote
  4. 4. Installed By The Design Team

    They change the radiators the design names as too small and keep the rest.

    Heat pump installation in Hazel Grove: step 4, balanced radiators
  5. 5. Commissioning

    Commissioning means setting the flow temperatures on site to the figures your design calls for, then testing the result.

    Heat pump installation in Hazel Grove: step 1, sizing to your house
  6. 6. Handover

    Before we leave you work the controls yourself, your warranty is registered in your name, and the first service goes in the diary with a reminder.

    Heat pump installation in Hazel Grove: step 6, registered and looked after

Rooms better suited to underfloor than a radiator get Virotherm, where the design calls for it.

Heat pump installation in Hazel Grove: step 4, balanced radiators Heat pump installation in Hazel Grove: step 3, radiators balanced Heat pump installation in Hazel Grove: step 3, a fixed quote Heat pump installation in Hazel Grove: step 4, balanced radiators Heat pump installation in Hazel Grove: step 1, sizing to your house Heat pump installation in Hazel Grove: step 6, registered and looked after
Heat pump installation in Hazel Grove: horizontal-feel composite of outdoor units on back and side walls (copy) /: install-only heat pump on the REAR wall of a gritstone terrace with bracket, pipework and condensate run, beside a real install tile; the one slot worth a new generation (copy)

From Bullock Smithy To Today’s Semis: Finding The Unit’s Spot In Hazel Grove

The village grew along the Manchester to Buxton road and took the name Hazel Grove in 1836, and close to three in four households there now live in a semi or a detached house.

A semi or a detached house gives the unit more than one wall to choose from, and that choice sets the pipe run you pay for and the noise at next door’s window. Stockport Council handles planning in Hazel Grove under the national rules:

  • A unit up to 1.5 cubic metres counts as permitted development if it passes the noise check, 37 dB(A) one metre outside the neighbour’s nearest window.

  • A wall facing the road is fine at ground-floor level and needs planning permission higher up.

  • The 1-metre boundary gap no longer applies (29 May 2025), which brings the side of a semi into play.

  • A listed house needs listed building consent first.

The survey fixes the spot before the price, so the quote covers the work from that wall and nothing gets moved later.

Hazel Grove’s Heating, Then The Line Your Heat Pump Has To Clear

Two Census figures from the ward and the target we design to.

  • 85%
    of Hazel Grove ward households heated with mains gas alone

    Census 2021

  • 73%
    of households there live in a semi or a detached house

    Census 2021

  • 3.5 to 4.0
    Target SCOP, where the house allows it

    Our design target

Heat pump installation in Hazel Grove: composite: unit on wall bracket, cylinder valves and gauge, engineer in the van

Cost per unit, October to December 2026 price cap

  • Electricity per kWh
    26.32p
  • Gas per kWh
    7.97p

Ofgem, energy price cap unit rates, GB average paying by Direct Debit.

SCOP 3.3

With gas at 7.97p and electricity at 26.32p, your heat pump needs a SCOP of 3.3 to match the gas bill. Anything above it beats it.

We aim the design at 3.5 to 4.0, and the quote shows where your house lands.

Electricity carries no VAT until 31 March 2027 while gas carries 5%. Once VAT returns to electricity at today’s cap, the match point rises to about 3.5.

“It’s just warm all the time”

Hear firsthand from our customer Fraser about how installing a heat pump has transformed his day to day living.

We’ve turned his cold 18th-century end terrace house into a comfortable, efficient home. No more waiting for the boiler to heat up the house in the morning.

Fraser’s property now sits at a consistent 19°C all year round.

Fraser, heat pump customer

Before You Book: Four Hazel Grove Heat Pump Doubts, Settled

Illustration of a bare stone house wall, before the heat pump brackets and unit are fittedIllustration of a Stiebel Eltron heat pump fitted on galvanised wall brackets against a stone wall, with its pipework run down the wall.Visualisation
Visualisation of a typical air source heat pump installation on wall brackets. Not footage of a real job.
  • Our boiler still works. Is it too early to look at a heat pump?

    Earlier gives you room to choose. The survey and the written quote cost you nothing, and if the sums for your house favour staying on gas, the quote says so in plain figures.

  • What if the heat pump ends up dearer to run than our gas boiler?

    It could if the design fell short of a SCOP of 3.3 at today’s prices. Ours aims at 3.5 to 4.0, and the quote sets your own house’s figure beside your gas so you see the margin before you sign.

  • I’ve heard they’re really expensive to install.

    Fitting one costs more than a boiler swap. You weigh that against the running cost next to your gas, both printed in the quote, and our heat pump costs guide shows what installs cost across the country.

  • Will the outdoor unit swamp a small back garden?

    Permitted development caps a unit on a house at 1.5 cubic metres, and the model’s manual sets the clear space around it. The survey measures your garden against both before the spot goes into the design.

Can I get the grant?

The Boiler Upgrade Scheme takes £7,500 off an eligible air source or ground source heat pump. Off-gas homes replacing oil or LPG heating get £9,000 instead, on applications made by 31 March 2027.

Grant claims run through MCS certification, and ours is in progress. Ask at the survey and you get the current position, explained straight.

Hazel Grove Heat Pump Questions: Lead Times, Planning, Coverage And Guarantees

Work back from the install itself, which runs a week to a month on site, and add the survey and the written design before it. Our office replies to your form within one working day, and the quote fixes the install dates.

Not in most cases. A unit within 1.5 cubic metres that passes the noise check at next door’s window counts as permitted development, and a road-facing wall stays allowed at ground-floor level. A listed building needs consent first.

Yes, and High Lane on the A6 as well. Bramhall and Poynton have their own pages, heat pumps in Bramhall and heat pumps in Poynton, and Disley, further along the A6, has heat pump installation in Disley. The rest of the borough sits on our Stockport heat pump page.

Your electricity bill, which moves the sums in the heat pump’s favour. A panel heater turns each unit it draws into one unit of heat, a design at a SCOP of 3.5 turns it into three and a half across the year, and 357 households in the ward heated this way at the 2021 Census.

A heat pump runs on mains electricity, and solar or a battery joins later where your roof and usage make the sums work. Our full renewables package shows how the three fit together.

We stand behind the fitting for two years under our workmanship guarantee, and at handover we register the manufacturer’s warranty in your name. The heat pump servicing page covers the yearly visit that keeps the system on its design figures.

Tell Us About The House

The job, your part of Hazel Grove and about how old the boiler is.

Google Reviews From Our Customers