MVHR installation for Disley homes: a white Mitsubishi Electric Lossnay MVHR unit on a raised platform in a sunny boarded loft, with insulated ducts to the gable wall and down to the rooms and its condensate drain running through a trap

MVHR Installation In Disley, Sized To Whichever Era Your House Comes From

We measure your house room by room, design the airflow from the same survey as your heating, and fit a Mitsubishi unit on a fixed quote.

  • Gas Safe Register mark, First Point gas engineer registration 930763
  • F-Gas Register mark, First Point registration FGAS3028681
  • Heat Geek trained
  • Stiebel Eltron certified installer
  • Which? Trusted Trader
Finance through Ideal4Finance

Spread The Cost Of Your Install

  • APR (fixed) 12.9%
  • Loans from £1 to £30,000
  • Finance over 12 to 120 months
  • Ask for finance with your quote
  • We agree any deposit with you before you apply

Representative example: £8,000 purchase, £2,000 deposit, £6,000 credit over 48 months at 12.9% APR (fixed). 48 monthly payments of £160.67. Total repayable £7,712.03. Total cost £9,712.03.

First Point Plumbing & Heating is an Introducer Appointed Representative of Ideal Sales Solutions Ltd, t/a Ideal4Finance. Ideal Sales Solutions Ltd is a credit broker and not a lender (FRN 703401). Finance available subject to status. There are risks involved in taking out a loan and you should ensure you can make all payments on time and in full; failure to do so can lead to financial difficulties and have a negative impact on your credit score.

MVHR installation for Disley homes: an open boiler casing with the heat exchanger exposed during a service

A Disley House Upgraded Bit By Bit Ends Up With Unplanned Ventilation

New windows one decade and a fuller loft the next leave the bathroom fan doing the work for the whole house.

Double glazing went in, then loft roll, then a new front door, each one fixing a draught. The condensation that used to clear by mid-morning now sits on the bedroom glass until lunchtime, because the house has no planned way left to move air.

The question to settle first:

  • “If the house is airtight, do we still need MVHR?”

A tighter house holds on to its warmth and to the damp air from cooking and showers. Heat recovery sends the damp air out and passes most of its warmth to the fresh air coming in, and we size it from the room-by-room survey that sizes your heating.

MVHR In Disley, Sized From The Same Numbers As Your Heating

Our lead engineer measures heat loss, the volume of each room and the power each one has available, then designs the ventilation against those figures.

  • Airflow worked out room by room before we choose a unit

  • A Mitsubishi MVHR unit sized to your house and its heat loss

  • Duct routes, unit position and airflow rates drawn with your heating, on one set of drawings

  • A fixed quote with the survey included, and our 2-year guarantee on the workmanship, running beside the manufacturer’s warranty on the unit

MVHR installation for Disley homes: a white Mitsubishi Electric Lossnay MVHR unit on a raised timber platform in a boarded loft, seen from the loft hatch, with four insulated ducts taped onto its top spigots, two foil ducts running to round terminals on the stone gable and two grey ducts feeding plenums whose radial ducts drop under the loft insulation, powered from a switched fused spur on the post

Stale Air Out, Fresh Air In, Through A Disley Loft

Scroll through the loop an MVHR unit runs in a Disley house: damp air out of the wet rooms, filtered air into the bedrooms and living room, and the warmth handed across in the core.

  1. Stale Air Leaves The Wet Rooms

    Damp air is pulled out of bathrooms and kitchens and carried outside.

    • Extract Valve
    • Extract Duct
    • Exhaust Duct
    • Exhaust Terminal
    • Stale Air
  2. Fresh Air Comes Back Filtered

    Outside air comes in through the filters and is supplied to the rooms you live in.

    • Intake Terminal
    • Intake Duct
    • Supply Duct
    • Supply Valve
    • Fresh Air
  3. The Core Keeps The Warmth

    Both streams pass through the heat exchanger, so most of the warmth stays inside.

    • Heat Exchanger Core
    • Fresh Air Filter
    • Extract Filter
    • Supply Fan
    • Extract Fan
  4. Sized From The Heating Survey

    Ductwork and airflow are sized from the numbers used for your heating, so nothing is measured twice.

    • Unit
    • End Panel
    • Lid
    • Controller

What An MVHR Installation In Disley Includes

Six stages for one fixed price, with the team that designs your system fitting it.

Your written quote covers each stage below.

  1. You Send The Form

    Tell us which rooms run damp or stuffy and what work the house has had, and our office replies within one working day.

    MVHR installation for Disley homes: step 1, photos or a short visit
  2. Measured Room By Room

    Our lead engineer measures heat loss and room volumes in person and looks at the loft and cupboards for duct routes before naming a unit.

    MVHR installation for Disley homes: step 2, a system filter as standard
  3. One Design For Air And Heat

    Duct routes, unit size and airflow rates go onto the same drawings as your heating.

    MVHR installation for Disley homes: step 4, balanced radiators
  4. A Fixed Quote

    The unit and the price sit in writing together before we order anything, with the time on site and the disruption agreed.

    MVHR installation for Disley homes: step 3, a fixed quote
  5. Fitted By The Designers

    The team that drew the design runs the ductwork and sites the unit where the drawings put it.

    MVHR installation for Disley homes: step 5, fitted this week
  6. Proved And Handed Over

    We prove the airflow rates room by room, show you the controls and set up reminders for the system checks.

    MVHR installation for Disley homes: step 6, full report and certificate

Mitsubishi MVHR units, chosen from your room volumes and heat loss once the survey is done.

MVHR installation for Disley homes: step 1, photos or a short visit MVHR installation for Disley homes: step 2, a system filter as standard MVHR installation for Disley homes: step 4, balanced radiators MVHR installation for Disley homes: step 3, a fixed quote MVHR installation for Disley homes: step 5, fitted this week MVHR installation for Disley homes: step 6, full report and certificate
MVHR installation for Disley homes: boiler service collage: a boiler with its casing open and a flue analyser probe

Stone Cottages, Inter-War Semis And 1970s Houses In One Village

In Disley and Lyme Park, the Valuation Office counts 25% of homes as built before 1919, 18% between 1919 and 1939, and 35% in the years from 1945 to 1982.

Each era leaks in its own places, and each upgrade closes some of them. A stone cottage near the church loses air round its floorboards and old frames, while a 1970s house with new windows and a fuller loft may have few gaps left. The survey finds out where your house sits before we size anything.

  • A post-war house after an upgrade. The regulations ask that replacement windows leave a home no worse ventilated than before. MVHR meets that and recovers heat from the air on its way out.

  • A pre-1919 cottage. If no window or insulation work is planned and the house stays draughty, heat recovery has little to work with, and we tell you so at the survey.

  • Two conservation areas. Cheshire East lists Disley village centre and Higher Disley. The outside terminals are the part of an MVHR system anyone sees, so we settle their position, and any permission, at the design stage.

  • Lyme Park next door. Lyme Park’s estate falls within the Peak District National Park and the village itself doesn’t, and the survey checks which planning authority covers your address.

Your design starts from your own measurements, so the unit moves the air your rooms need and keeps the warmth you have paid for.

The Disley Housing Figures Behind An MVHR Design

Two figures about the village and one about the job, to have in mind before the survey.

  • 35%
    of homes in Disley and Lyme Park built between 1945 and 1982 (Valuation Office, 2025)
  • 25%
    built before 1919, the stone cottages and older terraces
  • 3 to 4
    weeks for a retrofit, agreed in your quote; a new build takes 1 to 2

The age of your house shapes how much air it loses through gaps, and the length of a retrofit shapes how you plan the weeks around the work.

MVHR installation for Disley homes: a fitted boiler with its casing on and a system filter beneath

“It’s just warm all the time”

Hear firsthand from our customer Fraser about how installing a heat pump has transformed his day to day living.

We’ve turned his cold 18th-century end terrace house into a comfortable, efficient home. No more waiting for the boiler to heat up the house in the morning.

Fraser’s property now sits at a consistent 19°C all year round.

Fraser, heat pump customer

Four Doubts To Clear Before MVHR Goes Into A Disley House

MVHR installation for Disley homes: a boiler pressure gauge and expansion vessel close up
  • Will the house feel draughty with air moving all day?

    The air arrives through ducted valves set in the ceilings, and the design sets how much each room gets. The flow stays gentle and away from where you sit, with the windows shut.

  • Will it clear the condensation on the bedroom windows?

    The unit pulls damp air out of the kitchen and bathrooms on a constant loop, without waiting for someone to open a window. Damp coming through a wall from outside is a building repair, and MVHR won’t cure it.

  • Does it replace my gas boiler?

    MVHR moves the air, and your boiler or heat pump keeps the house warm. We design the two together, so the ventilation suits the heating you have or the one you are planning.

  • How much will MVHR cost for my house?

    We price it after the survey has measured your rooms, and the number we write down then is the number you pay.

MVHR In Disley: Timing, Planning And Your Heating

A retrofit takes three to four weeks and a new build one to two. Your quote states the time on site and the disruption to expect, agreed before we start.

We settle the duct runs, where the unit sits and where the outside terminals go during the design, and check them against the rules for Disley village centre or Higher Disley before we promise you anything. A listed home needs listed building consent first.

Yes. Mention it when we survey and both systems come out of one design, so no ductwork has to dodge heating pipes already in place. For the heating, read heat pump installation in Disley.

Yes, both. Our home town has its own page for MVHR installation in New Mills, and our main MVHR installation page explains how we design and fit.

Tell Us About Your Disley House

The rooms that run damp or stuffy, any work done on the windows or loft, and how to reach you. Our office passes it to our lead engineer.

Google Reviews From Across The High Peak